DXP D1616 User Manual 41
Cable lengthm
EQ Values
DRIVE Values
Input cable
Out cable
1.5
1.5
0-5
0-3
1.5
3
0-5
0-3
1.5
16.5
0-4
1-3
1.5
30
0-5
1-3
3
1.5
0-1
0-3
3
3
0-4
0-3
3
16.5
0-1
1-3
3
30
0-4
1-3
EDID study: EDID is extended display identification data, used to identify
the input video display information. When DXP D1616 is unable to detect
the input signal, but the input signal can be normal in the display, the use of
EDID Study function will copy the output port is connected to the input port
of the monitor of the EDID, the device can identify the input signal. Interface
as shown:
Comm Setup: When control DXP D1616 via windows control program, set
the COM first. For example, set CommPort as COM1 which is checked
from device manager, set BoudRate to as 9600, Click [OK] after setting.