Rgblink DXP D1616 User Manual Manual de usuario Pagina 73

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 76
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 72
DXP D1616 User Manual 73
according to SN sending command and SN receiving command. The
premise that PC sends the 5th command is already received the first
command reply.
You can reduce the sending command and wait for receiving time by using
SN flow control.
Frame format
Sending and receiving frame format as follows, including protocol data
uses ASCII code, such as 0 x02 means 0 x30, 0x32.
Send
Receive
Go back following data when receive does not support command or error:
Symbol
Byte
Definition
Note
CMD
1
CMD
DAT1
1
0xFF
DAT2
1
0xFF
DAT3
1
0xFF
DAT4
1
0xFF
Basic Setting
Model
Symbol
Byte
Definition
Note
CMD
1
0x68
DAT1
1
0x01
DAT2
1
Specification
DAT3
1
Specification
DAT4
1
0 no use
DAT2 = 0x16 DAT3= 0x16 Specification DXPV1616,DAT2 and DAT3
means matrix size if there is enable customers setting model.
DAT2 = 0x08 DAT3= 0x08 Specification DXPV0808
Factory Reset:
Protocol data
16
F
1
<
1
Protocol data
16
T
1
<
1
>
1
>
1