Symbol
Byte
Definition
Note
CMD
1
0x68
DAT1
1
0x06 (Factory Reset
DAT2
1
0 no use
DAT3
1
0 no use
DAT4
1
0 no use
Saving Mode Setting:
Symbol
Byte
Definition
Note
CMD
1
0x68
DAT1
1
0x08(Save) 0x09Call
DAT2
1
1-241~24 saving modes
DAT3
1
0 no use
DAT4
1
0 no use
Read/write matrix information:
Symbol
Byte
Definition
Note
CMD
1
0x70
DAT1
1
0x10 (Write) 0x11(Read)
DAT2
1
Output way No. (0-16 or ff )
DAT3
1
Input way No. (0-16)
DAT4
1
0no use
Index according to the output way when read the matrix information.
Input way = 0 Output way = 1-16 means close the corresponding output
way
Input way = 0 Output way = 0 means close all output ways
Input way= 0 Output way = 0 Command is illegal, no treatment
Input way =1-16 Output way = 1-16 means switch the corresponding way
Input way = 1-16 Output way = ff means will switch input way to output
way
Read board software version number:
Symbol
Byte
Definition
Note
CMD
1
0x6A Regulate other function
DAT1
1
0x01(read) Read software version number
DAT2
1
0~255Version number high
DAT3
1
0~255Version number low
DAT4
1
0
Display mode: high. Low. Such as: 1.1